FLEX 2000 sealing compound
vapour- and waterproof sealing compound

article number 120610

FLEX 2000

Water pressure test

20 aluminum pouches per carton Water pressure test

Prior to application: Heat Flex 2000 to appox. 35-40 ° by placing it in warm water for at least 30 minutes

Add to notice list

The most important information at a glance

article number:
120610
article group:
450 - Flex 2000 + Zubehör
GTIN:
4251689531408
customs tariff number:
32149000
packing unit:
pc
sales quantity unit:
1 Stk
weight per:
pc = 0.9 kg
material:

polyolefin

colour:
grey
density:
1,6 g/cm³ (DIN EN ISO 1183-1)
consistency:

paste-like, non-sagging

odour:

odourless

solvent content:

solvent free

application temperature:

appox. + 5 ° C bis +35° C

subsurface temperature:

approx. + 5 ° C bis +35° C

required amount:

approx. 1,6 kg per litre void

test certificate / approvals:

Test report

MFPA Leipzig

Nr.: U/5.1/08-043

cleaning of tools:

with universal cleaner following use

shelf life:

approx. 2 years at 20˚ C

 

waterpressuretightness:
up to max. 0,75 bar ( 7,5 m water coumn)
storage:
Store in undamaged and unopened orginal packaging in a dry place out of direct sunlight.
disposal:
Can be disposed of at municipal waste landfill sites, taking into account the local waste disposal regulations.

Preparation:

The substrate must be free from grease, tar, oil and loose particles.
Suitable substrates are: concrete, brick, mortar, plaster and all other mineral construction materials, as well as ceramics, PVC, polyethylene and polypropylene.
Clean the inside of the duct using a suitable brush to remove dust, sand, and any loose particles.

Prior to application, FLEX 2000 is warmed to approx. 35 - 40 °C by placing in hot water to ensure optimum consistency and workability


Installation:

Before applying FLEX 2000, a securing block of a two-component PUR foam is applied in the duct at a depth of approx. 15 cm.
The FLEX 2000 cartridge is then inserted into the cartridge applicator and FLEX 2000 paste injected into the annular gap of the two-component securing block, starting at the back and working towards the front.The layer must be at least 12 cm thick.
After sealing cable ducts, jiggle the cables slightly and fill any cavities with FLEX 2000.
Always ensure that the cable is free of tension and strain after sealing.The sealing compound is then pressed in firmly and smoothed with a metal filler knife leaving a depression approx. 1 cm deep, which is sealed with fast-curing cement to additionally secure the mouth of the duct.
To feed through a new cable, the mortar cap is removed and the cable is pushed through the sealing compound. The duct is then re-sealed using FLEX 2000.

Inflowing water


Insert the flexible nozzle into the duct and seal it with FLEX 2000 starting from the securing block.


Fill the duct slowly spirally from the center outwards with FLEX 2000.


Fill the duct completely with FLEX 2000.


Smooth down the FLEX 2000 sealing compound with a spatula, set back approx. 1 cm.


Close the duct with fast-curing cement and smooth it flush with the surface.

Status: 23.03.2022


FLEX 2000 in in-situ concrete

Download DWG

Download PDF

Accessories

suitable accessories

Contact us

We are happy to answer your questions

Please enter name
please_enter_company
please_enter_city
Please enter email
Please enter subject
Please enter message

Please fill the following captcha to reduce spam.

Please enter captcha.

We are not allowed to get in touch if you do not agree with our data privacy statement.