MASTER-SEAL ledkæde Ø 500 mm-V2A
til medierør Ø 311-326 mm

artikelnummer 110443

MASTER-SEAL modulær tætning

Test af vandtryk

medium pipe outer Ø 311 bis 326 mm 8 elements Type 600 in stainless steel

MPA- test up to 30 m watercolumn

Tilføj til meddelelsesliste

De vigtigste oplysninger på et øjeblik

switch_to_language DE
switch_to_language GB
switch_to_language FR
switch_to_language NL
switch_to_language IT
switch_to_language ES
switch_to_language CZ
switch_to_language PL
switch_to_language RO
switch_to_language DK
switch_to_language SE
switch_to_language NO
switch_to_language FI
switch_to_language RS
switch_to_language RU
switch_to_language GR
switch_to_language TR

Gå til Youtube

artikelnummer:
110443
Artikelgruppe:
445 - Master Seal A2+vz+Einzelglieder
GTIN:
4251689529832
toldtariffens nummer:
40169300
Pakkeenhed:
chain
salgsmængde enhed:
1 chain
vægt pr.:
chain = 14.7 kg
materiale:
Trykplader: polyamidforstærket
.
Tætningselement: EPDM-gummi
.
Bolte/møtrikker: rustfrit stål V2A
farve:
Trykplader: rød
Tætningselementer: sort
Skruer/møtrikker: sølv
Skruer:

M20

.
Antal skruer:

8

.
Bredde på tværs af fladerne:

30 mm

.
maks. drejningsmoment:

130 Nm (dimensionsstabile medierør)

.
Installationsdybde:

140 mm

.
Vandtrykstæthed:
3 barer
Medium rør:
311 til 326 mm

Supply takes place completely ready to be installed.
The MASTER-SEAL modular seal consists of individual sealing modules, each containing a rubber element, two moulded plastic parts and a screw with nut.
The screws and nuts are available in V2A material or in a galvanised version.
Required tooling:
Cleaning material, possibly PROTECT EP resin, measuring tool, torque wrench.


Before installing the MASTER-SEAL modular seal, the inside of the core drill hole and the outside of the gas, water, sewage pipes as well as the cables have to be cleaned.
The medium pipes / cables must be dimensionally stable in the sealing area and must not be damaged.


When installing a MASTER-SEAL modular seal in a core drill hole,
the inside of the core drill hole has to be preserved with an epoxy
resin (PROTECT EP resin).
The preservation serves to obtain a smooth surface and also as
protection of the cut reinforcement steels against corrosion.


The MASTER-SEAL modular seal is supplied as an open chain.
To close the chain, the last connecting screw must be loosened and removed.
To do this, loosen the plastic part with the nut from the screw and then pull the screw completely out of the rubber.


Push the two rubber ends into each other.


Insert the screw through the holes in both rubber ends to fix the closed chain.


After the plastic part has been reassembled with the nut, the
MASTER-SEAL modular seal is ready for installation.


Push the MASTER-SEAL modular seal over the medium pipe, insert both into the preserved core drill hole and position the MASTER-SEAL modular seal appropriately.
The MASTER-SEAL modular seal must be installed as close as possible to the outside of the wall ( earth-side, water-side).
Take care that the nuts can be controlled and retightened later.
The nuts have to be placed on the air-side.


Tighten the screws clockwise one after the other with a torque wrench.
This procedure must be repeated several times until the specified maximum torque is reached.
This procedure guarantees uniform pressing of the rubber parts against the walls.
The torque must be checked after approx. 2 hours, after the first release of tension on the rubber parts, and if necessary the screws must be retightened.


Fully assembled medium pipe incl. MASTER-SEAL modular seal.


When using a MASTER-SEAL modular seal in combination with an existing installation, the "open" modular seal is placed around the existing medium pipe and closed as described at the beginning.
Proceed as shown above.

Status: 23.03.2022


MASTER-SEAL in lining pipe precast wall

Download DWG

Download PDF

MASTER-SEAL in core drill hole precast wall

Download DWG

Download PDF

MASTER-SEAL in lining pipe in-situ concrete

Download DWG

Download PDF

MASTER-SEAL in core drill hole in-situ concrete

Download DWG

Download PDF

Kontakt os

Vi svarer gerne på dine spørgsmål

Indtast venligst navn
Indtast venligst firma
Indtast venligst by
Indtast venligst e-mail
Indtast venligst emne
Indtast venligst besked

Udfyld venligst følgende captcha for at reducere spam.

Indtast venligst captcha.

Vi må ikke kontakte dig, hvis du ikke er enig i vores erklæring om databeskyttelse.