Tôle d'étanchéité 120 Rouleau VB2
entièrement revêtu sur les deux faces

numéro d'article 070464

Rouleaux de tôle d’étanchéité VB

test de la stabilie CE Test de résistance à l'eau sous pression

packed in carton
width 120 mm
thickness 0,9 mm
incl. 30 mounting brackets and
incl. 2 fixing clips

water pressure test by MFPA Leipzig
groundwater neutral

Ajouter à la notice

Aperçu des informations les plus importantes

Youtube

numéro d'article:
070464
groupe d'articles:
213 - Dichtblech VB Rollen h = 80, 120, 240 mm
GTIN:
4251689511240
numéro tarifaire:
73269098
Conditionnement :
Rôle
unite de quantité de vent:
20 m
Matériau:

St 37, galvanisé
. Revêtement spécial : Plastique polymère renforcé par un tissu

.
Couleur:
Noir
length of joint sheet metal:

20 m

Height of joint sheet metal:

120 mm

thickness of special coating:

approx. 0,15 mm

total thickness:

approx. 0,9 mm

test certificate / approvals:

Test report PB 5.1/15-146-2
 MFPA Leipzig

suitable for zones with frequently varying water levels :

yes

corresponds to:

Utility class A for the wear classes 1 and
 2 in accordance with the WU guideline

Substances according to the SVHC list contained or proportional weight ≥0.1%:

No

conform to REACH Guideline:

Yes

packaging:

carton (40 x 40 x 20 cm)
 1 roll
 2 fixing clips
30 mounting brackets 

48 cartons per pallet

Domaine d'application thermique:
- 20°C bis 90°C
résistance testée à la pression d'eau:
jusqu'à max. 1,6 bar ( 16 m de colonne d'eau)
stockage:
Conserver dans l'emballage d'origine intact et non ouvert, au sec et à l'abri de la lumière directe du soleil.
mis au rebut:
Peut être éliminé dans des décharges d'ordures ménagères en respectant les dispositions locales en matière d'élimination des déchets.

Remove the bottom half of the parted protective foil from the special coating.


Place the VB joint sheet metal in the centre of the rising wall on top of the upper reinforcement layer.
Push the mounting brackets with a maximum distance of 70 cm over the sheet metal and fix them to the upper reinforcement layer with binding wire.
The embedment depth in the concrete must be at least 3 cm and must not be more than half the height of the sheet metal.

PLEASE NOTE!! The coating of the joint sheet metal VB1 must face the waterlogged side!


The VB joint sheet metal must overlap by at least 6 cm in the area of the joint, in the straight sections and also in the corner area.


To do so, the upper protective foil must be turned back in the area subsequently to be joined.


Overlap the VB joint sheet metal by at least 6 cm and press the two ends firmly together.
The joint must be glued over its full height and entire surface to prevent subsequent water permeation.
There must be no contamination on the adhesive surfaces that could interfere with bonding.


Secure the joint with one of the fixing clips provided and fold the protective foil back onto the special coating.


Prepared joints in the straight sections as well as the corner area.

Once the foundation slab has been concreted, and before the wall formwork is closed or the double wall elements have been set up, the remaining protective foil must be removed.
The concreting of the wall base and corresponding preparations must be carried out in accordance with the established technical standards.

Status: 23.03.2022


Installation in precast wall

Télécharger DWG

Télécharger PDF

Installation in in-situ concrete

Télécharger DWG

Télécharger PDF

Contactez nous

We are happy to answer your questions

S'il vous plâit mentionner le nom
please_enter_company
please_enter_city
S'il vous plâit mentionner la adress e-mail
S'il vous plâit mentionner l'objet
S'il vous plâit mentionner le message

Please fill the following captcha to reduce spam.

Veuillez saisir le captcha.

En manque de votre consentement nous ne pouvons pas accepter votre demande de contact