clamping range Ø 555-570 mm
article number 091252
-
high-pressure test up to 80m water column
-
animal excretions
-
silage effluent
-
diluted sulphuric acid
-
methane gas
The most important information at a glance
modified TPE
approx. 1,17 kg/dm³
50 ± 5 Shore A
approx. 6,5 N/mm²
approx. 380%
no
yes
landfill sites, taking into account the
local waste disposal regulations.
The RONDO Protect sealing collar is supplied ready-to-install with two stainless steel clamping straps for fixing.
Choose the correct size of RONDO Protect sealing collar corresponding to the outer diameterof the medium pipe to be waterproofed.
Soiled pipe walls must be cleaned prior to installing the RONDO Protect sealing collar.
Soaking in warm water (approx. 10 minutes) makes the sealing collar even easier to install, espacially at low temperatures.
The RONDO Protect sealing collar is pulled on from the spigot end before the pipe is installed.
The RONDO Protect sealing collar should be mounted centrally on the wall/floor plate.
The minimum concrete cover of 5 cm must not be undercut.
The distance to the surrounding reinforcement or other components must be at least 3 cm.
Apply lubricant to the clamping range of the strap, then tighten the clamping straps sufficiently using a screwdriver to prevent the RONDO Protect sealing collar from shifting.
During concreting, ensure thorough compacting around the RONDO Protect sealing collar in order to prevent defects/rock pockets.
Der RONDO Protect Sealing collar is positioned in the center of the concrete component.
It reliably and permanently prevents water penetration at the outer pipe wall.
Status: 26.07.2022
Contact us